B22 Cold Light Head Adapted to an Omega B66 Enlarger

Installation:

  • Cut rubber strip into 3 pieces - each 2 inches long.

  • Remove front panel of your B66 enlarger

  • Apply either acetone or lighter fluid to coated side of each rubber strip separately. When tacky, cement one strip to the inside back of your enlarger. cement each of the remaining two strips either side between the screw lugs. See figure 1.

  • Place plastic diffuser element into square recess in the bottom of your enlarger.

  • Insert the B22 unit into the enlarger, so that it rests flush against the diffuser.
    This will automatically position the unit properly over the negative area.

  • Now remove the bulb in your enlarger and drill a hole in its right side as shown in figure 2.

  • Screw a female receptacle into the bulb socket and plug in 2-prong plug. Draw the 3-prong plug through the hole and connect to the power pack.

  • Now, re-install the B22 unit as described in bullet #4, and replace the front slide cover of your enlarger.

Operation

  • Turn on switch of your enlarger cord and leave it on for the duration of any operating period. This activates the thermostat control which maintains the B22 unit at optimum operating temperature.

  • Allow the B22 unit to warm up for approximately 10 minutes before making any exposures.

 

If B22 head does not operate properly, check the following:

  • Did you plug the cord out of the back of your enlarger into an outlet? (110 Vac)

  • Did you plug the cord out of the power pack into an outlet, or timer?

  • Is your timer plugged in?

  • Is the switch on your timer in the "on" position?

  • Are all plugs and connections made properly?

  • Check instructions again, step by step!

 

Thermostat Control

  • This feature is incorporated in all Aristo units. Thermo control maintains a continuous ambient warmth around the lamp insuring peak brightness at each start when operated through a timer or footswitch

    Turn on your thermo switch or plug in your thermo cord and allow your unit to warm up for about 5-10 minutes before making any exposure.

    To help speed up this warm-up period, the lamp may be turned on at the same time for about 3 minutes, then shut off. The unit is now ready to operate efficiently.

    The thermo control should be left on continuously for the duration of any day or working session.

Processing Recommendations:

  • Negatives: Develop negatives 20-30% longer than recommended for normal. This becomes the "Normal" negative for cold light printing

  • Paper: Expose paper so that full development time can be given. This will produce prints of good contrast and maximum quality, maintaining a full tonal range from the whitest highlights to the deepest blacks.

  • Maintenance and Care: Clean your unit periodically. With a damp cloth wipe your lamp, reflector and diffusion plate of dust and dirt which may accumulate. Keeping the until clean will help maintain optimum evenness, speed and contrast.

    With a minimum of care, your Aristo cold light unit will give you years of faithful and trouble free service. All units are thoroughly checked and tested before leaving the factory, and are guaranteed for 90 days against defects in workmanship and materials.

    When ordering replacement lamps, transformers or diffusion elements for your unit, please specify your unit model number and color of lamp desired, etc.

Caution:
Instructions are for guidance only.
Aristo/Voltarc will not be responsible for any damage to lamp
or lamp housing for items improperly installed.

     

Home | V54 Lamp | Spectral Distribution | Cold Light Heads | 1212 Installation | B22 Installation | B22 Adaptation | B23C Installation | Bessler 4x5 Installation | B67C Installation | D2 Installation | D2 Lamp Installation | DA10 Installation | DA10 Lamp Installation | DA17 Installation | DA17 Lamp Installation | D1414 Installation | D57 Installation | DL1200  Installation | EK57 Adaptation | General Installation | Omega 67C Installation | VCL4500 Installation | VCL4500 Lamp Installation | VCL4500 Temp Probe Installation | VCL4500 Adaptation | VCL8100 Installation | VCL-GR-DIMMER Installation

This site was last updated 01/09/08

Aristo Lighting Technologies Inc.
400 Captain Neville Drive
Waterbury, CT 06705
Tel: 203-575-3425  Fax: 203-575-3456

Send mail to customerservice@voltarc.com with questions and inquiries
Copyright © 2008 Aristo Grid Lamp Products, Inc.