Installation:

    • Remove condenser lens collar and carefully remove condensers.

    • Place the diffusion element into the bottom of the condenser lens collar and place the BES23C lamp housing into the collar on top of the diffusion.

    • Remove top cap supporting the tungsten lamp on the enlarger

    • With the cords coming out of the lamp housing toward the back of the enlarger, feed the cords thorough the opening in the op of the enlarger.

    • Replace the condenser collar with Aristo unit into the machine and lift bellow over the collar.

    • Connect the matching components of the plug between the power pack and the lamp housing- securely.

    • Primary cord coming out the lamp housing (two prong) operates thermo. This is plugged into any available 115 Vac outlet.

    • The plug out of the power pack is plugged into your timer. (three prong). (Turn switch to "on" position.) Leave slack on the cords coming out of the lamp housing to avoid lifting of unit when enlarger is raised or lowered.

Thermostat Control

  • This feature is incorporated in all Aristo units. Thermo control maintains a continuous ambient warmth around the lamp insuring peak brightness at each start when operated through a timer or footswitch

    Turn on your thermo switch or plug in your thermo cord and allow your unit to warm up for about 5-10 minutes before making any exposure.

    To help speed up this warm-up period, the lamp may be turned on at the same time for about 3 minutes, then shut off. The unit is now ready to operate efficiently.

    The thermo control should be left on continuously for the duration of any day or working session.

 

Processing Recommendations:

  • Negatives: Develop negatives 20-30% longer than recommended for normal. This becomes the "Normal" negative for cold light printing

  • Paper: Expose paper so that full development time can be given. This will produce prints of good contrast and maximum quality, maintaining a full tonal range from the whitest highlights to the deepest blacks.

  • Maintenance and Care: Clean your unit periodically. With a damp cloth wipe your lamp, reflector and diffusion plate of dust and dirt which may accumulate. Keeping the until clean will help maintain optimum evenness, speed and contrast.

    With a minimum of care, your Aristo cold light unit will give you years of faithful and trouble free service. All units are thoroughly checked and tested before leaving the factory, and are guaranteed for 90 days against defects in workmanship and materials.

    When ordering replacement lamps, transformers or diffusion elements for your unit, please specify your unit model number and color of lamp desired, etc.

Caution:
Instructions are for guidance only.
Aristo/Voltarc will not be responsible for any damage to lamp
or lamp housing for items improperly installed.

     

Home | V54 Lamp | Spectral Distribution | Cold Light Heads | 1212 Installation | B22 Installation | B22 Adaptation | B23C Installation | Bessler 4x5 Installation | B67C Installation | D2 Installation | D2 Lamp Installation | DA10 Installation | DA10 Lamp Installation | DA17 Installation | DA17 Lamp Installation | D1414 Installation | D57 Installation | DL1200  Installation | EK57 Adaptation | General Installation | Omega 67C Installation | VCL4500 Installation | VCL4500 Lamp Installation | VCL4500 Temp Probe Installation | VCL4500 Adaptation | VCL8100 Installation | VCL-GR-DIMMER Installation

This site was last updated 01/09/08

Aristo Lighting Technologies Inc.
400 Captain Neville Drive
Waterbury, CT 06705
Tel: 203-575-3425  Fax: 203-575-3456

Send mail to customerservice@voltarc.com with questions and inquiries
Copyright © 2008 Aristo Grid Lamp Products, Inc.