D2 Installation

01/15/08

Home
V54 Lamp
Spectral Distribution
Cold Light Heads
1212 Installation
B22 Installation
B22 Adaptation
B23C Installation
Bessler 4x5 Installation
B67C Installation
D2 Installation
D2 Lamp Installation
DA10 Installation
DA10 Lamp Installation
DA17 Installation
DA17 Lamp Installation
D1414 Installation
D57 Installation
DL1200  Installation
EK57 Adaptation
General Installation
Omega 67C Installation
VCL4500 Installation
VCL4500 Lamp Installation
VCL4500 Temp Probe Installation
VCL4500 Adaptation
VCL8100 Installation
VCL-GR-DIMMER Installation

 

General Installation for Omega D Series Enlargers: D2, D3, D5 & D6

Aristo units designed for installation on Omega D Series enlargers come in a single unit and are self-contained. These normally are equipped with two cords on the cold light head. The two pronged cord operates the lamp and may be plugged into your timer or footswitch. The three prong cord, which operate the thermostatically controlled heater, is plugged into any available 115 Vac outlet.

Installation:

  • Remove the condenser from the condenser lens collar. With a small hack saw, cut a 3/4 inch deep and 1/4 inch wide midway between any two keyed slots. Smooth this cut with a small file.

  • Place the diffusion element into the bottom of your condenser collar and your Aristo unit on top of it.

  • Bring this assembly up to the negative stage of your enlarger.

  • Bring the three prong (thermo) cord out through the notch in the collar and secure the collar onto the enlarger.

  • Plug in your enlarger light cord into your timer or footswitch. Plug the three prong (thermo) cord protruding through the notch into the nearest available AC outlet.

    If you wish to use your Aristo unit and your condensers interchangeably, it's a good idea to purchase another condenser lens collar. Changing then from a diffusion light to a condenser light would be fast and simple and would provide you with greater latitude and versatility in your print production.

    Alternate Method:

    • Remove top portion of your enlarger supporting the bulb and reflector.

      Bring both cords out through this opening. This eliminates the need to notch your condenser lens collar and may take somewhat longer to change from cold light to condenser printing.

Thermostat Control

  • This feature is incorporated in all Aristo units. Thermo control maintains a continuous ambient warmth around the lamp insuring peak brightness at each start when operated through a timer or footswitch

    Turn on your thermo switch or plug in your thermo cord and allow your unit to warm up for about 5-10 minutes before making any exposure.

    To help speed up this warm-up period, the lamp may be turned on at the same time for about 3 minutes, then shut off. The unit is now ready to operate efficiently.

    The thermo control should be left on continuously for the duration of any day or working session.

 

Processing Recommendations:

  • Negatives: Develop negatives 20-30% longer than recommended for normal. This becomes the "Normal" negative for cold light printing

  • Paper: Expose paper so that full development time can be given. This will produce prints of good contrast and maximum quality, maintaining a full tonal range from the whitest highlights to the deepest blacks.

  • Maintenance and Care: Clean your unit periodically. With a damp cloth wipe your lamp, reflector and diffusion plate of dust and dirt which may accumulate. Keeping the until clean will help maintain optimum evenness, speed and contrast.

    With a minimum of care, your Aristo cold light unit will give you years of faithful and trouble free service. All units are thoroughly checked and tested before leaving the factory, and are guaranteed for 90 days against defects in workmanship and materials.

    When ordering replacement lamps, transformers or diffusion elements for your unit, please specify your unit model number and color of lamp desired, etc.

Caution:
Instructions are for guidance only.
Aristo/Voltarc will not be responsible for any damage to lamp
or lamp housing for items improperly installed.

     

Home | V54 Lamp | Spectral Distribution | Cold Light Heads | 1212 Installation | B22 Installation | B22 Adaptation | B23C Installation | Bessler 4x5 Installation | B67C Installation | D2 Installation | D2 Lamp Installation | DA10 Installation | DA10 Lamp Installation | DA17 Installation | DA17 Lamp Installation | D1414 Installation | D57 Installation | DL1200  Installation | EK57 Adaptation | General Installation | Omega 67C Installation | VCL4500 Installation | VCL4500 Lamp Installation | VCL4500 Temp Probe Installation | VCL4500 Adaptation | VCL8100 Installation | VCL-GR-DIMMER Installation

This site was last updated 01/09/08

Aristo Lighting Technologies Inc.
400 Captain Neville Drive
Waterbury, CT 06705
Tel: 203-575-3425  Fax: 203-575-3456

Send mail to customerservice@voltarc.com with questions and inquiries
Copyright © 2008 Aristo Grid Lamp Products, Inc.