Installation:

  • Remove sheet metal screws

  • Separate the lamp housing and cover

  • Undo the connections between lamp and Transformer.
    (By unscrewing the wire nuts.)

 

 

  • At the electrode-cut the silicone between
    lamp reflector housing (metal) and glass
    electrode by a sharp knife or blade.

  • Cut the copper tie wire.

  • Carefully pull the lamp out from the clip.
    (Pull from position closer to the clip)

  • Position the new lamp over the clip. Push the lamp in the Clip.
    (By putting slight pressure at clip point only)

  • Connect one transformer black wire to one lamp wire.
    Repeat the same with the second black wire of the transformer to the other lamp wire.
    (Use the wire nuts you have removed in step 3.0

  • Put the cover back in position.

  • Put the sheet metal screws back.

  • Tire wire and Silicone is not necessary as they are put in for the safety of the lamp during shipping.

Caution:
Instructions are for guidance only.
Aristo/Voltarc will not be responsible for any damage to lamp
or lamp housing for items improperly installed.

     

Home | V54 Lamp | Spectral Distribution | Cold Light Heads | 1212 Installation | B22 Installation | B22 Adaptation | B23C Installation | Bessler 4x5 Installation | B67C Installation | D2 Installation | D2 Lamp Installation | DA10 Installation | DA10 Lamp Installation | DA17 Installation | DA17 Lamp Installation | D1414 Installation | D57 Installation | DL1200  Installation | EK57 Adaptation | General Installation | Omega 67C Installation | VCL4500 Installation | VCL4500 Lamp Installation | VCL4500 Temp Probe Installation | VCL4500 Adaptation | VCL8100 Installation | VCL-GR-DIMMER Installation

This site was last updated 01/09/08

Aristo Lighting Technologies Inc.
400 Captain Neville Drive
Waterbury, CT 06705
Tel: 203-575-3425  Fax: 203-575-3456

Send mail to customerservice@voltarc.com with questions and inquiries
Copyright © 2008 Aristo Grid Lamp Products, Inc.