General Installation for 4
x 5, 5 x 7 and 8 x 10 Enlargers
Aristo units designed for installation on 4 x 5, 5 x 7 and 8 x 10
enlargers come in a single unit and are generally self-contained. These
normally are equipped with two cords on the cold light head. The two
pronged cord operates the lamp and may be plugged into your timer or
footswitch. The three prong cord, which operate the thermostatically
controlled heater, is plugged into any available 115 Vac outlet.
Units to be installed on enlargers smaller than 4x5 come in two parts -
lamp housing and power pack. The two components connect together by a
cable.
Installation:
-
Remove the lamp
housing and all diffusion and heating resisting glass.
-
Set your adapter
frame with the diffusion element into your enlarger as close as
possible to the negative carrier.
-
Place your unit
into the adapter frame.
-
Plug two prong
cord into your timer or footswitch , and the three prong cord
(thermo) into the nearest available 115 Vac outlet.
-
Turn on the
thermo-switch on the side of your Aristo unit. Allow unit to warm up
for about 5 minutes prior to making your first exposure.
Thermostat
Control
-
This feature is
incorporated in all Aristo units. Thermo control maintains a
continuous ambient warmth around the lamp insuring peak brightness
at each start when operated through a timer or footswitch
Turn on your thermo switch or plug in your thermo cord and allow
your unit to warm up for about 5-10 minutes before making any
exposure.
To help speed up this warm-up period, the lamp
may be turned on at the same time for about 3 minutes, then shut
off. The unit is now ready to operate efficiently.
The thermo control should be left on continuously for the duration
of any day or working session.
Processing
Recommendations:
-
Negatives: Develop negatives 20-30% longer than recommended
for normal. This becomes the "Normal" negative for cold light
printing
-
Paper:
Expose paper so that full development time can be given. This will
produce prints of good contrast and maximum quality, maintaining a
full tonal range from the whitest highlights to the deepest blacks.
-
Maintenance and Care: Clean your unit periodically. With a
damp cloth wipe your lamp, reflector and diffusion plate of dust and
dirt which may accumulate. Keeping the until clean will help
maintain optimum evenness, speed and contrast.
With a minimum of care, your Aristo cold light unit will give you
years of faithful and trouble free service. All units are thoroughly
checked and tested before leaving the factory, and are guaranteed
for 90 days against defects in workmanship and materials.
When ordering replacement lamps, transformers or diffusion elements
for your unit, please specify your unit model number and color of
lamp desired, etc.
Caution:
Instructions are for guidance only.
Aristo/Voltarc will not be responsible for any damage to lamp
or lamp housing for items improperly installed. |