PIC 1 PIC 2
Remove Cover from power pack Unscrew the nut for the grounding wires using 1/2 drill bit
PIC 3 PIC 4
Using the hole from the grounding screw- enlarge this hole to a 1/2" diameter.  To re-attach the grounding wires, drill a new hole to the upper right approx. 1/4" dia, as in picture.
PIC 5 PIC 6
Cable from new dimmer switch as 3 wires:
Green = Ground;
Black = Line
White = Neutral
Place these three wires from the dimmer switch into the 1/2" hole and enclose with the plastic bushing. Compress bushing with pliers until secure in the 1/2" hole
PIC 7 PIC 8
Looking from inside the unit, re- attach the grounding wires to the grounding screw (Phillips screw) Install a crimp connector on black (Line) wire on the cable.
PIC 9 PIC 10
Front: Color Switch From back of the color switch, remove white wire from terminal on color switch
PIC 11 PIC 12
Place black (Line) wire from newly installed dimmer cable on the color switch terminal Cut connecter/lug off of the white (neutral) wire.

Strip wire and twist together with white wire from the new dimmer. Apply wire nut.

Plug green dimmer into the new connection.

Plug in power cords.

Turn on and adjust color switch to green light.

Turn on dimmer, adjust dimmer knob-  green lamp should adjust with dimmer.

Turn off power pack and put back cover back on unit

 

 

 

Caution:
Instructions are for guidance only.
Aristo/Voltarc will not be responsible for any damage to lamp
or lamp housing for items improperly installed.

     

Home | V54 Lamp | Spectral Distribution | Cold Light Heads | 1212 Installation | B22 Installation | B22 Adaptation | B23C Installation | Bessler 4x5 Installation | B67C Installation | D2 Installation | D2 Lamp Installation | DA10 Installation | DA10 Lamp Installation | DA17 Installation | DA17 Lamp Installation | D1414 Installation | D57 Installation | DL1200  Installation | EK57 Adaptation | General Installation | Omega 67C Installation | VCL4500 Installation | VCL4500 Lamp Installation | VCL4500 Temp Probe Installation | VCL4500 Adaptation | VCL8100 Installation | VCL-GR-DIMMER Installation

This site was last updated 01/09/08

Aristo Lighting Technologies Inc.
400 Captain Neville Drive
Waterbury, CT 06705
Tel: 203-575-3425  Fax: 203-575-3456

Send mail to customerservice@voltarc.com with questions and inquiries
Copyright © 2008 Aristo Grid Lamp Products, Inc.