VCL4500-C-Dual-Dim-110V Model Shown
- Complete
Variable Contrast Control from
Grade 0 to Grade 5 with 50 Settings
Over Entire Range without Using Filters
- Low Power
Consumption
- Fast
Consistent Exposures
- Maybe Used
with Any Timer
Light Head (2 lamps High
Intensity)
- Size:
7 11/16 L x 7 11/16 W x 4 5/16 H
-
Weight: 3.3 lbs.
-
Secondary Cable: 6'
-
Heater: Adjustable Thermostat Controller
- Power Supply:
120 VAC, 60 Hz, 195 Watts
- Fuse:
AGC 3 amp
- Size:
8" L x 8" W x 3.75" H
-
Weight: 10.2 lbs.
-
Primary Cord: 6' Long, 3-Prong Grounded
-
Relay: Built-in with 6' 2-Line Cord for Timer
Connection

-
LED intensity control
-
Red LED Display 0.0 up to 5.o in tenths.
-
Variable contrast control from grade 0 through grade 5 with 50
settings.
Maybe used to adjust speed on graded paper
-
Color selection 3 way rocker switch
-
Main power on/off lighted rocker switch with red lens
-
Normal/split printing mode switch
-
Zero adjustment for different variable contrast papers

VCL4500 Back View
Installation: Your diffusion
light source is equipped with two (2) high intensity lamps. They are
designed to give you peak spectral distribution in blue and green for
optimum control.
- Installation of your VCL4500 is fast and easy and only requires
removing the existing lamp housing and condenser lenses.
- On Beseler 4x5 units, just place the Aristo light head into
the upper bellows which should be left totally collapsed. It is not
necessary to focus for different negative sizes.
-
For the Omega D Series,
the
optional bracket
is required to attach the cold light to the four (4) raising and
lowering arms on the column.
Connect the cable from the light head into the back of the power
supply.
Plug the three-prong power cord into any 115 Vac outlet.
Plug the two-line cord into any 110 Vac timer with a 1.5 W or more
capacity.
Turn on the main power switch and allow 10 to 15 minutes for the
thermostatically controlled heating system in your light head to warm
the lamps to optimum operating temperature. This will insure consistent
light output during each exposure. Turning the lamps on for two to three
minutes at the start of a printing session is beneficial and will hasten
the warm-up.
Caution:
The lamps do generate moderate
amounts of heat on their own. Excessive on time can cause light loss.
This is a temporary condition. When turned off and allowed to cool to
the thermostat setting (95°F on the top of the lamp head) the light
level will increase and return to normal. Repeat overheating will
degrade the light output faster than normal and shorten lamp life.
Proper work habits are important and will insure consistency.

- #6 in ON position, #4 provides;
Blue Max: = blue only at maximum
brightness
Blue/Off: = blue only with fully adjustable
brightness control
Green/Blue: = Green and blue combined with blue
intensity being fully adjustable
- #6 in OFF position, #4 provides;
Blue Max: = blue only at maximum
brightness
Blue/Off: = off only
Green/Blue: = Green only, no blue
Note:
For printing without timer, cold light may be turned on and off
by plugging two line cord directly into a 110Vac outlet with an ON/OFF
switch Capability.


Optional Bracket for the Omega D Series
Enlargers

Wiring Diagram


Caution:
Instructions are for guidance only.
Aristo/Voltarc will not be responsible for any damage to lamp
or lamp housing for items improperly installed. |