VCL4500 Lamp
Installation
- To open light
head, remove four (4) 4-40 machine screws
(two on each side of the light head).

-
Remove
cable strain relief.
-
Remove
three (3) 6-32 machine screws
-
Undo
cable and lamp leads at terminal Block
-
Cut
Tie wires holding lamp to bars and remove lamps.

-
Open notches per Mod "A" on Plate.
-
Install blue lamp and wire in place as shown on photo copy of lamp
on plate,
See Mod "B".

-
Slip yellow lamp onto plate and over the top of the blue lamp into
position. Check for alignment in relation to the blue lamp. Make
sure that no part of the yellow lamp extends over plate. Slide the
yellow lamp back so that it's ends, "A", are exposed. Place a drop
of translucent silicone rubber "B" on each of ends "A", in four (4)
places, Mod B. Lifting the yellow lamp up at one
end, move it back into position over the blue lamp and place onto
the silicone drops. Holding the yellow lamp into position, stand
plate up on end with side "A" being down. Squeeze a drop of silicone
between the yellow and blue lamps at ends "C", in four places. Place
plate back in a horizontal position and check the position of yellow
lamp, adjusting if needed, and allow the silicone to cure over
night.
-
You are now ready to reassemble.
Caution:
Instructions are for guidance only.
Aristo/Voltarc will not be responsible for any damage to lamp
or lamp housing for items improperly installed. |